• Benth Top Water Hardness Meter for Lab
  • Benth Top Water Hardness Meter for Lab

Benth Top Water Hardness Meter for Lab

After-sales Service: Lifetime Maintenance
Warranty: 1 Year
Resolution: 0.01 and 0.1 Water Hardness Units
Accuracy: ±5% Fs
Temp. Compensation: (5 ~ 50)ºC (Automatic)
Working Ambient Temperature: (5~35)ºC
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YD200
Transport Package
in Cartoon
Specification
(160*190*70)mm/750g
Trademark
TOP
Origin
Zhejiang, China (Mainland)
HS Code
9031809090
Production Capacity
300 Set/Sets Per Week

Product Description



Introduction

* Bench top meter is used for measuring water hardness. (the total concentration of calcium ion and magnesium ion).
* Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode,
reference electrode and temperature probe. Replaceable measuring head, steady potential, quick response, easy to use.
* Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage
RS232 output, etc.
* Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three
units: ºfH(France),ºdH (Germany)and ºeH(UK) from WH-Link communication software.
* Equipped with B1,B2 and B3 calibration solution.
* Equipped with WH-Link communication software, connect testing data of meter to computer.


Specification
Water Hardness
Measuring range
(0 ~ 10)mmol/L;
(0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3);
(0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);
(0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);
(0 ~ 70)ºeH (England Degree)
Resolution
0.01 and 0.1 water hardness units
Accuracy
±5% FS
Temp. compensation
(5 ~ 50)ºC (automatic)
Calibration Solution
B1 Calibration Solution - 2.00×10-2 mmol/L
 
B2 Calibration Solution - 2.00×10-1 mmol/L
 
B3 Calibration Solution - 2.00 mmol/L
 
(B3Calibration Solution also can be used
for the soaking solution of electrode)
Calibration Mode
(a)B1/B2 Calibration-using B1 and
B2 Calibration Solution,
suitable for < 2.00×10-2 mmol/L low
concentration water quality,
for example, boiler water.
 
(b)Calibration-using B2 and
B3 Calibration Solution,
suitable for general water quality.
Temperature
Measuring range
0 ~ 60ºC
Resolution
0.1ºC
Accuracy
±0.5ºC
Other Technical
Parameter
Data storage
128 groups
Content Storage
serial number of measuring value,
measuring value, units, temperature,
ATC or MTC, date, time and calibration way.
Communication
Connector
RS232
Power
DC9V
Dimension and weight
(160×190×70)mm/750g
Quality and safe certificate
IISO9001:2000 and CE
working conditions
Ambient temperature
(5~35)ºC
ambient humidity
≤85%RH
Standard Kit Includes
 
1. Model YD300 water hardness meter
1set
2.Model 601-F water hardness electrode (With two measuring heads and one screw plug)
1pc
3. Model 602 Flexible electrode holder
1pc
4.250mL water hardness calibration solution (B1, B2 and B3)
1btl/each
5.20mL test cup
4pcs
6. Test cup pedestal
1pc
7. WH-Link communication software
1 pc
8. RS-232 communication cable
1pc
9. Operation manual
1book

 

Optional Accessories
 
Accessory Category
Description
Specification
Water hardness
electrode
601-F water
hardness electrode
Suited for measurement of
total concentration of calcium
ion and magnesium ion,
match YD200 meter, BNC+RCA connector
Water hardness
calibration solution
Water hardness
calibration solution B1
2.00×10-2 mmol/L, 500mL/250mL/100mL (bottle)
 
Water hardness
calibration solution B2
2.00×10-1 mmol/L, 500mL/250mL/100mL (bottle)
 
Water hardness
calibration solution B3
2.00 mmol/L, 500mL/250mL/100mL (bottle)
 
Plastic test cup
Specification: 20mL
Accessories
 
Test cup base
Place test cup on the base