Water Hardness
|
Measuring range
|
(0 ~ 10)mmol/L; (0 ~ 401)mg/L(Ca); |
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree); |
||
(0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree); |
||
(0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree) |
||
Resolution
|
0.01 and 0.1 water hardness units
|
|
Accuracy
|
±5% FS
|
|
Temp. compensation
|
(5 ~ 50)ºC (automatic)
|
|
Calibration Solution
|
B1 Calibration Solution - 2.00×10-2 mmol/L
|
|
|
B2 Calibration Solution - 2.00×10-1 mmol/L
|
|
|
B3 Calibration Solution - 2.00 mmol/L
|
|
|
(B3Calibration Solution also can be used for the soaking solution of electrode) |
|
Calibration Mode
|
(a)B1/B2 Calibration-using B1 and B2 Calibration Solution, suitable for < 2.00×10-2 mmol/L low concentration water quality, for example, boiler water. |
|
|
(b)Calibration-using B2 and B3 Calibration Solution, suitable for general water quality. |
|
Temperature
|
Measuring range
|
0 ~ 60ºC
|
Resolution
|
0.1ºC
|
|
Accuracy
|
±0.5ºC
|
|
Other Technical Parameter |
Data storage
|
128 groups
|
Content Storage
|
serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way. |
|
Communication Connector |
RS232
|
|
Power
|
DC9V
|
|
Dimension and weight
|
(160×190×70)mm/750g
|
|
Quality and safe certificate
|
IISO9001:2000 and CE
|
|
working conditions
|
Ambient temperature
|
(5~35)ºC
|
ambient humidity
|
≤85%RH
|
1. Model YD300 water hardness meter
|
1set
|
2.Model 601-F water hardness electrode (With two measuring heads and one screw plug)
|
1pc
|
3. Model 602 Flexible electrode holder
|
1pc
|
4.250mL water hardness calibration solution (B1, B2 and B3)
|
1btl/each
|
5.20mL test cup
|
4pcs
|
6. Test cup pedestal
|
1pc
|
7. WH-Link communication software
|
1 pc
|
8. RS-232 communication cable
|
1pc
|
9. Operation manual
|
1book
|
Accessory Category
|
Description
|
Specification
|
Water hardness electrode |
601-F water hardness electrode |
Suited for measurement of total concentration of calcium ion and magnesium ion, match YD200 meter, BNC+RCA connector |
Water hardness calibration solution |
Water hardness calibration solution B1 |
2.00×10-2 mmol/L, 500mL/250mL/100mL (bottle)
|
|
Water hardness calibration solution B2 |
2.00×10-1 mmol/L, 500mL/250mL/100mL (bottle)
|
|
Water hardness calibration solution B3 |
2.00 mmol/L, 500mL/250mL/100mL (bottle)
|
|
Plastic test cup
|
Specification: 20mL
|
Accessories
|
||
|
Test cup base
|
Place test cup on the base
|