Model
|
Bante900P
|
pH
|
|
Range
|
-2.000~20.000pH
|
Accuracy
|
±0.002pH
|
Resolution
|
0.1, 0.01, 0.001pH, Selectable
|
Calibration Points
|
1 to 5 points
|
Calibration Solutions
|
USA, NIST, DIN or User-defined
|
Temperature Compensation
|
0~100°C, 32~212°F
|
Compensation Mode
|
Manual or Automatic
|
mV
|
|
Range
|
-1999.9~1999.9mV
|
Accuracy
|
±0.2mV
|
Resolution
|
0.1, 1mV, Selectable
|
Calibration Points
|
1 point (Only for Relative mV mode)
|
Calibration Range
|
±200mV
|
Ion
|
|
Range
|
0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)
|
Accuracy
|
±0.5% F.S (Monovalent), ±1% F.S (Divalent)
|
Resolution
|
0.001, 0.01, 0.1, 1
|
Calibration Points
|
2 to 5 points
|
Calibration Solutions
|
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L
|
Temperature Compensation
|
0~100°C, 32~212°F
|
Compensation Mode
|
Manual or Automatic
|
Conductivity
|
|
Range
|
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
|
Accuracy
|
±0.5% F.S
|
Calibration Points
|
1 to 5 points
|
Calibration Solutions
|
10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
|
Temperature Compensation
|
0~100°C, 32~212°F, Manual or Automatic
|
Temperature Coefficient
|
0.0~10.0%/°C
|
Compensation Modes
|
Linear or Pure Water
|
Cell Constant
|
K=0.1, 1, 10 or User-defined
|
Normalization Temperature
|
20°C or 25°C
|
TDS
|
|
Range
|
0~100ppt (Max. 200ppt, depending on factor setting)
|
Accuracy
|
±1% F.S
|
TDS Factor
|
0.1~1.0 (Default 0.5)
|
Salinity
|
|
Range
|
0~10ppt (Max. 80ppt)
|
Accuracy
|
±1% F.S
|
Measurement Modes
|
Seawater or Practical Salinity
|
Resistivity
|
|
Range
|
0~100MΩ
|
Accuracy
|
±1% F.S
|
Resolution
|
0.01, 0.1, 1
|
Dissolved Oxygen
|
|
Range
|
0.00~20.00mg/L (or ppm)
|
Accuracy
|
±0.2mg/L
|
Resolution
|
0.01mg/L
|
Calibration Points
|
1 or 2 points
|
Temperature Compensation
|
0~50°C, 32~122°F, Automatic
|
Pressure Correction
|
60.0~112.5kPa, 450~850mmHg
|
Salinity Correction
|
0~50g/L
|
% Saturation of Oxygen
|
|
Range
|
0.0~200.0%
|
Accuracy
|
±2.0%
|
Resolution
|
0.1, 1%
|
Temperature
|
|
Range
|
0~105°C, 32~221°F
|
Accuracy
|
±0.5°C, ±0.9°F
|
Resolution
|
0.1°C
|
Calibration Points
|
1 point
|
Calibration Range
|
Measured value ±10°C
|
Others
|
|
Hold Function
|
Manual or Automatic
|
Stability Conditions
|
Low or High
|
Calibration Due
|
0 to 31 days
|
Power Off
|
Manual or Automatic (10, 20, 30 minutes)
|
Reset Function
|
Yes
|
Memory
|
Stores up to 500 data sets
|
Output
|
USB Communication Interface
|
Connector
|
BNC, 6-pin Mini Plug
|
Power Requirements
|
3×1.5V "AA" Batteries
|
Battery Life
|
Approximately 150 hours (Turn off the backlit)
|
Dimensions
|
170(L)×85(W)×30(H)mm
|
Weight
|
300g
|