Quality Lab Equipment Laser Analyzer

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
300
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Packing and Deliver
  • After Sales Service
  • FAQ
  • Company Profile
  • Customer Response
Overview

Basic Info.

Model NO.
WJL-608
Customized
Customized
Structure
Desktop
Material
/
Certification
CE
Application
Lab
Type
/
Province
Zhejiang
Transport Package
Carton or Customized
Specification
/
Trademark
TOP
Origin
China
HS Code
9031809090
Production Capacity
1000set/Sets Per Month

Product Description

Product Description

Quality Lab Equipment Laser Analyzer
 
Characteristics
•Work principle: The laser particle size analyzer is based on the full measuring range of Mie scattering theory, sufficiently considering the optics nature such as sample and decentralized medium refraction coefficient and so on. On the basis of laser illuminate size and the size distribution regular pattern of scattering light energy that comes from the sample inversely calculates out sample group.
•Technique feature: The laser particle size analyzer work principle is well-developed, hardware design is very reasonable, the product is designed according to the international engineering standard ISO-13320, GMP Regulation and absorbs England, America, Germany, and other countries' well-developed experience in the size analysis, all features of the product are domestically and leading.
•lluminant: The laser particle size analyzer adopts He-Ne's laser make illuminant, the wavelength is 0.6328 micron, the wavelength is short, string breadth is narrow, stability is good, and laser power source and laser tube service life is more than 25000 hours.
•Light electricity probe: The laser particle size analyzer light electricity system is designed uniquely. The primary detector is one, of many assist detectors, presenting non-uniform intercourse and three-dimension fan-shaped ranges matrix rank. The largest test examination horn angle attainability is up to 135°
•Light route: The laser particle size analyzer adopts a measuring range designed, the convergent light route is unique, decreasing Fourier lens, as a result, the measurement range is broader, the resolution is higher, and the error is minimal.

Specification


Dispersion method
Specifications
Dimensions
Weight(Net)
WJL-602
Wet
1. Measurement range:0.1-600μm
2. Error:<±1%(national standard materials D50)
3. Repetitiveness deviation: <±1%(national standard materials D50)
1000×330×320mm
WJL-606
Wet
1,Measurement range:0.05-800μm
2,Error:<±1%(national standard materials D50)
3,Repetitiveness deviation: <±1%(national standard materials D50)
WJL-608
Wet
1,Measurement range:0.02-1200μm
2,Error:<±1%(national standard materials D50)
3,Repetitiveness deviation: <±1%(national standard materials D50)
WJL-612
Dry
1. Measurement range:0.1-600μm
2. Error:<±1%(national standard materials D50)
3. Repetitiveness deviation: <±1%(national standard materials D50)
Main system: 1000×330×320mm
Dry sampling system:350×330×300mm
WJL-616
Dry
1,Measurement range:0.1-800μm
2. Error:<±1%(national standard materials D50)
3. Repetitiveness deviation: <±1%(national standard materials D50)
WJL-618
Dry
1,Measurement range:0.1-1200μm
2. Error:<±1%(national standard materials D50)
3. Repetitiveness deviation: <±1%(national standard materials D50)
WJL-622
Wet/Dry
1,Measurement range:0.1-600μm/
2,Error:<±1%(national standard materials D50)
3,Repetitiveness deviation: <±1%(national standard materials D50)
Main system: 1000×330×320mm
Dry sampling system:350×330×300mm
Wet sampling system:350×330×300mm
WJL-626
Wet/Dry
1,Measurement range:0.05-800μm
2,Error:<±1%(national standard materials D50)
3,Repetitiveness deviation: <±1%(national standard materials D50)
WJL-628
Wet/Dry
1,Measurement range:0.02-1200μm
2,Error:<±1%(national standard materials D50)
3,Repetitiveness deviation: <±1%(national standard materials D50)

Packing and Deliver

Quality Lab Equipment Laser Analyzer

Quality Lab Equipment Laser Analyzer

After Sales Service

Quality Lab Equipment Laser Analyzer

We have a professional after-sales team with global service coverage and a 24-hour time difference free to provide you with solutions.

FAQ

1. Are you a manufacturer or not?
Yes, we are. We have more than 300 workers and 26680 square meters of production base in Zhejiang province which is close to Shanghai and Ningbo port. Welcome to come and visit our factory.

2. How do you guarantee the quality of your products?
We have passed ISO9001 / 14001 / 45001 quality system certification. And has a professional quality inspection team of more than 30 inspectors. Adhere to the strict quality control of each process from raw materials to packaging.

3. What is your after-sales service?
The warranty time is 1 full year, lifelong maintenance.

4. How long is your delivery lead time?
It is generally 3-5 days, but it will vary according to different products and quantities.
 
5. OEM available?
Yes, OEM is acceptable. Please contact us for specific information.

Company Profile

Quality Lab Equipment Laser Analyzer
TOP Cloud-Agri was founded in 2008. It is a national high-tech enterprise specializing in the design, development, manufacture, and sales of agricultural testing instruments, laboratory equipment, and smart agriculture. The core products of the company are testing instruments in seed shape measurement, seed breeding, sampling, cleaning, storage, seed vigor and health research, plant physiology, soil physical properties analysis, crops quality analysis, food safety detection, agriculture produces quality testing, plant protection, pest forecast, and monitoring, weather monitoring, water quality detection, smart agriculture solutions, and other general laboratory devices.

Quality Lab Equipment Laser AnalyzerQuality Lab Equipment Laser AnalyzerQuality Lab Equipment Laser Analyzer

ΔCertificate
 
Quality Lab Equipment Laser Analyzer
 
TOP Cloud-Agri has passed ISO9001:2015,ISO14001:2015,ISO45001:2018 .Now we are speeding up the construction of Three Major Base.

Up to now, TOP Cloud-Agri has joined the National 863 project, State Star Plan Project, and other multiple national scientific research projects, and the company was awarded 18 national Invention patents, 40 utility model patents, 7 appearance patents, 140+ product software copyright, 39 software product registration; Meantime, TOP Cloud-Agri has been identified as Zhejiang Provincial Academician Workstation, Provincial Enterprise Research Institute.

Customer Response

Quality Lab Equipment Laser Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier